NStatusSerial NumberLocationChanged onComments
1+4CERN2022-01-25
Replaced nMCM 3
nMCM 12261 replaced by 12344 on 25.01.18
25.01.22 Tigran, DAmir, Silvia. replaced nMCM 12344 with 12846. failing DAC scan. Still failing after replacement
2+76CERN2022-01-25
Update Tests KS
wide pedestal investigation (was not due to nMCM at the end..)
Replaced nMCM 12342 by 12269 on 20.03.18
excanged (25.1.22, Tigran, DAmir) nMCM 12269 to 12836 because broad pedestal
3+103CERN, PP62021-05-10
PPM was in KIP for Repair. All MCMs exchanged. The new population as of April 30th 2010
CAN 81 needs R3 resistor in order to flush CAN FW
Currently unplugged in TestRig because without CAN board
CAN board back after repair, seems to be working now
Updating database for module replacements in 2018
Installed in P1, PP6 during TREX installation, on PP6PPM0 replacing PPM #100, found to be with power up problems
4-100KIP2021-05-10
It was found to be problematic at power up during TREX installation. Back to KIP for repair
5+95CERN 1042019-12-12
Hardware:
Replaced the following 5 MCMs:
* MCM SerNr 4429 (slot# 4) with MCM SerNr 3123 --> errors: broken ASIC diode (temp mesurement) and bad FADC data (digChan# 3)
* MCM SerNr 4428 (slot# 5) with MCM SerNr 3124 --> errors: bit# 4 & 8 permanently missing in the JEP-LVDS, and bad FADC data (digChan# 2)
* MCM SerNr 4434 (slot# 8) with MCM SerNr 3125 --> errors: bad FADC data (digChan# 3)
* MCM SerNr 4440 (slot# 11) with MCM SerNr 3126 --> errors: bad FADC data (digChan# 4)
* MCM SerNr 4443 (slot# 14) with MCM SerNr 3127 --> errors: PHOS4 initialization error.
Va & KS
Taken out from P1 (it was in PP0 PPM15) because bad channel 01f0801, first spiky then died. Problem probably due to AnIn3 (179). Now in testrig, last slot
Update database for module replacements in 2018
Back in HD for repair. Removed working CAN board # 95 and installe in PPM 121, now under power in testrig 104, last slot
AnIn board # 3 (179, causing problems in data taking in 2018) replaced by (#229). PPM back to CERN, b104 TR, slot 5, equiped with TREX_v2
CAN board with new FW was also installed on it
6- 121CERN 1042019-12-12
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Remove +
Given to ZDC
Currently unplugged in testrig because without CAN board
problems uploading the CAN FW. Independent from the CAN board
Plgged in TR 104, last slot, with CAN board # 95
bad AnIn 179 installed here, back to HD for repairs
7+154CERN 1042019-12-12
Hardware:
Replaced MCM SerNr 4138 (slot# 4) with MCM SerNr 3179 due to bad JEP-LVDS data
. Victor Andrei
Hardware:
CAN R4k7 implemented.
PPM was in KIP for Repair. All MCMs beside MCM16 exchanged. The new population as of April 29. 2010
Remove +
Remove +
V6 error reported on the front-panel display. nMCM numbers obsolete (point to old MCMs).
V6 error understood (it was induced by a wrongly placed GND probe). But the board shows issues on +3.3V on power-up and when more than 6 nMCM are mounted, which affects the operation of some power regulators on the TREX (i.e. ATX_1V0 and KTX_0V95 have 0V output).
apparently the power problem was only due to CAN old FW. Solved updating new CAN FW. PPM now installed at CERN n TR 104, slot #7 with TREX (not cabledwith LVDs)
8-22KIP S42018-11-27
Firmware: DAC offsets for signals going to MCMs 13 & 14 (AnIn 4) set only after several tries. F/w used: Kambiz' latest version.
Victor Andrei
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
AnIn board problem (drifting values). Will be sent back to HD for more investigation
9+41CERN TestRig2018-10-11
Test in KSLAB ok
PPM# 41 was removed from USA15 pp3-ppm8 on 2010-07-19 because of readout problems, glink timeouts and BC number mismatches, see https://atlasop.cern.ch/elog/ATLAS/ATLAS/98982.
PPM# 41 was removed from USA15 pp3-ppm8 on 2010-07-19 because of readout problems, glink timeouts and BC number mismatches, see https://atlasop.cern.ch/elog/ATLAS/ATLAS/98982.
spare module from HD to CERN
Updated notation of location from -104- to -TestRig-
10+49CERN TestRig2018-10-11
MCM 2161<->3072 in MCM13
elog link Pavel Weber
Module was removed from P1 (formerly pp1-ppm02) due to parity errors on link(s) to jep00-jem03.
Correctly marked as being in TestRig
11+81CERN TestRig2018-10-11
MCM replacement:
The MCMs 2685, 2686, 2687 and 2688 (positions 3 to 6) were replaced with MCMs 2785, 2786, 2787 and 2788 due to incomplete DB entries.
Victor Andrei
PPM was in KIP for Repair. All MCMs exchanged. The new population as of April 29. 2010
Update Tests KS
Given to ZDC
Replaced two nMCMs by spares. Original nMCMs moved to P1 to replace two nMCMs there (pp2-ppm0-nmcm4 and pp2-ppm11-nmcm2)
swapped CAN 103 with 179
12+82CERN TestRig2018-10-11
MCM replacement:
Replaced MCM 2704 with MCM 2780 due to an ambiguous entry in DB: the subnr and the waffer code entries of MCM 2704 are identical to the same entries of MCM 2837 (which is recorded in DB as well). The MCM 2704 was removed from the board for further investigations, and the PPM was tested once again (single board tests) with the new MCM (2780).
Victor Andrei
MCM12 exchanged #2710 --> #2477
Update Tests KS
not possible to program the CAN (42)
Currently unplugged in testrig because without CAN board
Plugged back CAN board after repairs, now seems to be good
Updating database for nMCM exchanges in 2018
13+92CERN2018-10-11
LVDS Tests (Full Crate)
: The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Hardware (LVDS errors):
Replaced the following MCMs:
* MCM SerNr 4359 (slot #2) with MCM SerNr 3139 due to LVDS-JEP errors (bit#8 permanently missing);
* MCM SerNr 4369 (slot #10) with MCM SerNr 3140 due to LVDS-JEP errors (bit#4 permanently missing).
VA & KS
Hardware (Analogue errors):
Replaced the following MCMs:
* MCM SerNr 4361 (slot #3) with MCM SerNr 3141 due bad FADC data on digChan# 4;
* MCM SerNr 4363 (slot #5) with MCM SerNr 3142 due to bad FADC data on digChan# 3 and 4;
* MCM SerNr 4376 (slot #14) with MCM SerNr 3143 due bad FADC data on digChan# 1 aand 3;
* MCM SerNr 4378 (slot #16) with MCM SerNr 3144 due to bad FADC data on digChan# 3.
VA & KS
Hardware:
Replaced MCM SerNr 4377 (slot# 15) with MCM SerNr 3154 due to large FADC data width seen on the AnCh# 4.
The change was actually done on 20.06.2008, and the PPM was retested in the new configuration (only on the light crate setup)
VA & KS
PPM was in KIP for Repair. All MCMs except 12-14&16 exchanged. The new population as of April 29. 2010
Replaced nMCM 11071 by 10392 on 18.05.18
14+108CERN2018-10-11
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
nMCM 11955 replaced by 11251 on 18.09.18
15+130CERN TestRig2018-10-11
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Hardware:
The module was brought back to Heidelberg for investigations. We could not reproduce the error reported from CERN and, also, we did not find any other problem (during Single Board Tests).
Victor Andrei
b>Hardware:
replaced MCM 8 SerNr 3881 -> 3202
Bad Temp. Diode
replaced MCM 12 SerNr 3887 -> 3145
sometimes ADC Data Problems
CAN R4k7 implemented
KS
PPM was in KIP for Repair. MCM01, MCM06, MCM09 and MCM11 exchanged. CAN-Brd changed to #179. The new population as of April 30th 2010
Update Tests KS
Replaces PPM 51 in Test Reg Slot 12
swpped can 179 with 103
CAN (103) power cycles the board after ~ 5min and then switches the PPM completely OFF after other ~ 5min
Problem solved with new CAN FW 5.8.1
Correctly marked as being in TestRig
16+141CERN TestRig2018-10-11
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
PPM was in KIP for Repair. CAN-Brd changed to #42. All MCMs beside MCM09 exchanged. The new population as of April 30th 2010
Correctly marked as being in TestRig
17+99CERN2018-07-24
Location Ambiguity:
Check if the module was really sent to CERN!
Victor Andrei
PPM was in KIP for Repair. MCM09, MCM14 & MC16 exchanged.
The PPM is actually in HD not at CERN
from HD to CERN 104, spare board
down in USA15 and plugged in PP2 slot 0 as spare, after having replaced PP0PPM15 for broken AnIn
18+136CERN2018-07-24
Readback:
Found LUT readback errors for MCM# 2 (SerNr 1227), chan# 3 (2nd serIntf, first channel). Replaced the MCM with MCM SerNr 3111.
Victor Andrei
Hardware:
do not found MCM2 SerNr 3111 ???
found MCM2 SerNr 3171
CAN R4k7 implemented
KS
Update Tests KS
used PPM, before plugged in PP2 as spare board, as PP0PP15, snce the prevous one had a bad AnIn. Problem fixed
19+87CERN2018-03-26
Hardware:
replaced MCM 2 SerNr 4533 -> 3247
No Serial Interface
replaced MCM 13 SerNr 4551 -> 3245
Analog Ch2 Bad ADC values
CAN R4k7 implemented
Update Tests KS
simulation errors
20+138CERN2017-09-19
nMCM replacement: https://atlasop.cern.ch/elisa/display/318286
Fixing a previous mistake: It was nMCM 11571 and not 11579 which was exchanged. See: https://atlasop.cern.ch/elisa/display/333335
Remove nMCM 10389 which was apparently entered here by mistake.
nMCM #11567 was replaced by #11653 due to timing problems: https://atlasop.cern.ch/elisa/display/308255
21+142CERN2017-09-19
Two nMCM replaced due to problems. https://atlasop.cern.ch/elisa/display/356943
22255KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
23239KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
24241KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
25240KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
26250KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
27246KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
28251KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
29243KIP ATLAS Lab2017-08-04
Mounted nMCMs for eventual TREX tests
30+97CERN2017-07-04
Hardware:
Replaced MCM SerNr 4477 (MCM slot# 3) with MCM SerNr 3115 due to bad data format on the the ASIC serial interface. Also, replaced MCM SerNr 4480 (MCM slot# 6) with MCM SerNr 3116 (no data on both serial interfaces).
Victor & Klaus
Hardware:
Replaced MCM SerNr 4473 (MCM slot# 1) with MCM SerNr 3117 due to bad FADC data (digChan# 0) and LVDS lock missing (CP, chan# 1). Also, replaced MCM SerNr 4476 (MCM slot# 2) with MCM SerNr 3118 (bit#9 - the 2nd MSB - permanently missing in the JEP LVDS output).
Victor & Klaus
Hardware (LVDS errors, Full Crate Test):
Replaced MCM SerNr 4478 (slot# 4) with MCM SerNr 3155 due to bad LVDS data on digChan# 3 (affects both CP and JEP output).
Victor Andrei.
Hardware:
Replaced MCM SerNr 4492 (slot# 14) with MCM SerNr 3153 due to bad FADC voltage window observed for the AnCh# 1.
The change was actually done on 20.06.2008, and the PPM was retested in the new configuration (only on the light crate setup).
VA & KS
Replace 12189 with 12252
31+12CERN2017-03-20
Firmware: DAC offsets for signals going to MCMs 13 & 14 (AnIn 4) set only after several tries. F/w used: Kambiz' latest version.
Victor Andrei
MCM11 1556 to 3235 Phos4initerror KS MCM9 1554 to 3248 changed before ? KS MCM14 1560 to 3237 changed before ? KS MCM16 1562 t0 3236 changed before ? KS
Test in KSLAB ok
Given to ZDC
Mistake in comment before; PPM was not given to ZDC. Remains in Testrig
it was in testrig slot 11. Switching off proble (after 10 min). Swapped CAn card with PPM 12 and problem moves with the CAN card. module is a good spare for P1 now. (CAN FW version compatible with P1)
Module was installed in USA15 as pp1-ppm02.
32145KS-Lab2017-02-24
MCM 3385 changed to 3201 KS
PPM was in KIP for Repair. All MCMs exchanged. The new population as of April 30th 2010
Remove +
Remove +
33245ZDC - CERN2015-06-02
Equipped with nMCMs for transport to CERN for ZDC.
Added AnIns to Database
34253ZDC - CERN2015-06-02
Equipped with nMCMS for transport to CERN fot ZDC.
Added AnIns to Database
35247ZDC - CERN2015-06-02
Equipped with nMCMs for transport to CERN for ZDC.
Added AnIns to Database
36248ZDC - CERN2015-06-02
Equipped with nMCMs for transport to CERN for ZDC.
Added AnIns to Database
37+236CERN 104 R-B212015-05-20
changed MCM serNr 4799 in slot 13 with MCM serNr 2952. Problem: failures of the LUT slope method in the digital channel number 3.
Back from ZDC
38+249CERN 104 R-B212015-05-20
Cannot upload the debug file from the long-term LVDS tests. The file is too large.
VA
Back from ZDC
39-35CERN2015-03-24
Hardware:
Retested for CERN.
KS
Hardware:
CAN R4k7 implemented
KS
PPM was in KIP for Repair. All MCMs exchanged. The new population as of April 30th 2010
PPM not powering down after MCM replacement and not responding to VME requests. Found that the J0 VME connector of the motherboard was damaged. However, the backplane connector looks ok, which indicates that the damage has not been produced during the (re)insertion of the module in the crate.
PPM exchange: PPM (serial no 38) from pp01-pp09 has been swapped with spare PPM (serial no 35) from pp03-ppm08 in order to diagnose and eliminate JEP parity errors.
40+38CERN2015-03-24
MCM replacement: The MCM mounted in slot 8 was replaced (previously serial nr.1936, now serial nr.2500).
Victor Andrei
MCM replacement:
Mounted back the MCM 1936, but the DB ambiguity still not fixed.
Victor Andrei
nMCM replacement: The nMCM mounted in slot 2 was replaced (previously serial nr.10966, now serial nr.11214).
PPM exchange: PPM (serial no 38) from pp01-pp09 has been swapped with spare PPM (serial no 35) from pp03-ppm08 in order to diagnose and eliminate JEP parity errors.
41+51CERN2014-11-27
Hardware:
Replaced MCM SerNr 2206 (slot# 9) with MCM SerNr 3128 due to permanent PHOS4 initialization problem.
VA & KS
LVDS Tests (Full Crate):
Could not upload the latest debug file, because the file is too big. Therefore, the current debug file available in the database describes previous tests. The new file must be uploaded by hand.
Victor Andrei
MCM replacement: MCM2: 2199<->3060
elog link
Pavel
nMCM configuration not working properly in Slot 8, even destroying EEPROM configuration. Will be investigated further at KIP.
42+2CERN2014-08-31
43+1CERN2014-08-31
Electrical test: PPM power controller shuts down with additional modules in the crate (i.e. TCM).
Victor Andrei
44+3CERN2014-08-31
45+7CERN2014-08-31
46+9CERN2014-08-31
47+10CERN2014-08-31
LVDS Tests (full-crate): The debug file is not (yet) uploaded to database. The module was tested over the night, and the size of the produced debug file exceeds the maximum currently allowed by database.<\br> Victor Andrei
48+11CERN2014-08-31
49+13CERN2014-08-31
50+14CERN2014-08-31
51+16CERN2014-08-31
52+17CERN2014-08-31
53+18CERN2014-08-31
54+19CERN2014-08-31
55+25CERN2014-08-31
56+26CERN2014-08-31
PHOS4: Problems to initialise PHOS4 of MCM #11. To be investigated.
Victor Andrei
57+29CERN2014-08-31
58+31CERN2014-08-31
AnIn1, channel 15, wrong resistor mounted (remounted to 1 kOhm). MCM#11 replaced (previously 2186, currently 2012), due to low signal on analogue channel_2. Victor Andrei
59+33CERN2014-08-31
DAC and MCM problems
Errors obeserved at CERN, module is back to Heidelberg more investigations.
Victor & Klaus
Analogue Tests Found open DAC pin on AnIn#2 and bad ADC data for the analogue channel nr.4 of MCM#14. Soldered the DAC pin, replaced MCM#14 (previously serNr 2128, currently serNr 3083) and redid the analogue tests.
Victor & Klaus
LVDS Tests:
Redone, no error observed with the new configuration.
Victor Andrei
Verification:
Retested the module before to send it back to CERN. No error observed.
Victor Andrei.
MCM replacement
MCM12: 2125<->3066 elog link
Pavel Weber
60+39CERN2014-08-31
61+37CERN2014-08-31
62+40CERN2014-08-31
63+43CERN2014-08-31
LVDS Tests (full-crate):
The JEP LVDS tests were incomplete due to a CMC time-out problem. Module initially sent to CERN in July 2007 and brought back to Heidelberg for test completion in December 2007.
Victor Andrei.
LVDS Tests(Full-crate set-up):
Redone for both LVDS data to CP and to JEP, no error observed.
Victor Andrei
Verification:
Tested the module once again before to send it back to CERN. No error observed during the whole chain of tests.
Victor Andrei
64+44CERN2014-08-31
65+45CERN2014-08-31
66+64CERN2014-08-31
Hardware:
replaced MCM 4 SerNr 2535 with SerNr 3243 Analogch1 ADC bad data error. CAN 4k7 implemented.
Update Tests KS
67+54CERN2014-08-31
MCM replacement
MCM14: 2471<->3065
elog link
Pavel Weber
Update Tests KS
68+89CERN2014-08-31
This PPM is at CERN (Cr.1, Slot10) acc. to RA's listing on Okt.07 ? ? ?
Location of the module:
The module is in Heidelberg and it needs to be retested after it failed initial LVDS tests. The module which is believed to be at CERN (as actually planned) is PPM# 99 (see the comments for this module).
Victor Andrei
LVDS Tests (Full Crate):
Klaus has replaced MCM#8 (initially serNr 4327, now serNr 2955) due to bad values provided by the 'temperature' diode. The problem occured after the module has passed the Single Board Tests (see the temperature map created during the Full Crate Tests for PPM# 122 and compare it with the similar map for PPM# 100; see also the date when the tests were done). Also, Klaus has replaced MCM#5 (initially serNr 4317, now serNr 2956) due to missing externalBCID bit (initially not detected during the Single Board Tests).
Victor Andrei
The externalBCID bit is missing from the ROD buffer (it's not set though it should be).
Victor Andrei
69+90CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
70+94CERN2014-08-31
71+105CERN2014-08-31
MCM replacement
MCM02: 3420<->3067
elog link
Pavel
72+128CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
73+102CERN2014-08-31
74+107CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
LVDS Tests (Full Crate):
The high temperature value recorded on the MCM in slot#13 was due to an unsoldered pin of the Multiplexer chip. The problem is fixed now and the temperature values are as expected.
Victor Andrei
MCM2 replaced
4609<->3076
elog link PW
75+110CERN2014-08-31
76+111CERN2014-08-31
77+112CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
78+114CERN2014-08-31
79+115CERN2014-08-31
80+125CERN2014-08-31
MCM 3714<->3071 in MCM9
elog link
Pavel Weber
81+122CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
82+123CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
83+131CERN2014-08-31
84+132CERN2014-08-31
Hardware:
Replaced MCM SerNr 2958 (MCM slot# 1) with MCM SerNr 3119 (only in BcMux mode, bit# 5 - bit# 3 of the LUT value - is missing for chan# 1, LVDS to CP output). Also, replaced MCM SerNr 3845 (MCM slot# 13) with MCM SerNr 3120 (found bit#5 of the LVDS to JEP output missing permanently).
va & ks
Hardware:
Replaced MCM SerNr 3836 (slot#5) with MCM SerNr 3122 due to bad FADC data observed during SPI-DAC scans.
va & ks
85+135CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
86+137CERN2014-08-31
MCM 3921 in MCM8 replaced
3921<->3070
elog link
Pavel Weber
87+140CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
88+106CERN2014-08-31
89+124CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
90+144CERN2014-08-31
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
91+149CERN2014-08-31
92+150CERN2014-08-31
Hardware:
Found possible asymmetric LVDS output for MCM# 15, ch# 2. Replaced the MCM (SerNr 4094) with another MCM (SerNr 3102) and redid all tests with the new MCM.
Victor Andrei
93+151CERN2014-08-31
94+152CERN2014-08-31
Hardware:
Found possible asymmetric LVDS output for MCM# 6, ch# 1. Replaced the MCM (SerNr 4102) with another MCM (SerNr 3103) and redid all tests with the new MCM.
Victor Andrei
95+153CERN2014-08-31
96+155CERN2014-08-31
Hardware:
Found possible asymmetric LVDS output for MCM# 16, ch# 3. Replaced the MCM (SerNr 4175) with MCM SerNr 3104. Also, replaced MCM# 9 (SerNr 4167) and MCM# 10 (SerNr 4169) with MCM SerNr 3105 and MCM SerNr 3107 due to bad FADC data (digCh# 4 on both MCMs). Redid all tests with the new MCMs.
Victor Andrei
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Replaced MCM 4166 with MCM 3075 in MCM8
elog link
Pavel Weber
97+157CERN2014-08-31
Changed MCM after 6Weeks burnin MCM 04 4203->3188 ADC4-Bit Err MCM 05 4204->3189 ADC3-Bit Err MCM 09 4211->3218 ADC-Bit width MCM 10 4209->3190 ADC-Bit width
Changed MCM after 6Weeks burnin MCM 04 4203->3188 ADC4-Bit Err MCM 05 4204->3189 ADC3-Bit Err MCM 09 4211->3218 ADC-Bit width MCM 10 4209->3190 ADC-Bit width
Changed MCM after 6Weeks burnin MCM 04 4203->3188 ADC4-Bit Err MCM 05 4204->3189 ADC3-Bit Err MCM 09 4211->3218 ADC-Bit width MCM 10 4209->3190 ADC-Bit width
98+158CERN2014-08-31
99+23CERN2014-08-28
Chanced MCM15 1747 to 3239 bad analog ch1 adcdata width phos4test KS
Test in KSLAB ok
100+32CERN2014-08-28
3 MCMs exchanged: MCM03: #2098 -> #2479
MCM06: #2102 -> #3139
MCM14: #2110 -> #2480
101+117CERN2014-08-28
MCM4 Replaced: Was 4654, now it's 4618
102+34CERN2014-07-07
103+46CERN2014-07-07
MCM 2056 MCM12
2056<->3077
elog link
104+52CERN2014-07-07
Update Tests KS
105+53CERN2014-07-07
Problem: Do not know MCM Nr. 11 KS
106+55CERN2014-07-07
MCM 2456 in MCM15 replaced by MCM 3073 elog link
Problem: Do not know MCM Nr. 11 KS
107+56CERN2014-07-07
Update Tests KS
108+77CERN2014-07-07
Update Tests KS
Update Tests KS
109+78CERN2014-07-07
Update Tests KS
Update Tests KS
110+79CERN2014-07-07
Update Tests KS
Update Tests KS
111+85CERN2014-07-07
MCM Replacement:
MCM13 2743->3047
elog
112+86CERN2014-07-07
MCM replacement:
Replaced MCM 2722 (position 8) with MCM 2789 due to ambiguous DB entries. The PPM was retested (single board tests).
Victor Andrei
Update Tests KS
113+84CERN2014-07-07
MCM replacement:
The MCM 2756 (position 10) was replaced with the MCM 2790 due to ambiguous DB entries.
Victor Andrei
The PPM was successfully retested with the new MCM.
Victor Andrei
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
114-88KIP HD2014-07-07
LVDS Tests (Full Crate)<\u><\b>:
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
PPM not powering up in USA15 after MCM replacement. Probably the power controller is faulty.
115+98CERN2014-07-07
Hardware:
replaced MCM 2 SerNr 4516 -> 3163
Bad ADC Data
replaced MCM 6 SerNr 4520 -> 3170
No Serial Interface both
replaced MCM 9 SerNr 4524 -> 3164
Bad ADC Data
replaced MCM 11 SerNr 4526 -> 3169
No Serial Interface both
CAN R4k7 implemented
PPM #98 was in KIP for Repair PPM #98: All MCMs exchanged. The new population as of April 29. 2010:
Update Tests KS
116-109KIP HD2014-07-07
Hardware:
ANIN NR 158 CH9 OPA 650 changed. KS
Update Tests KS
CALIPPR FPGA configuration failed for the nMCM in slot 10. Found that the FPGA DONE signal does not reach ReM FPGA due to an improper soldering of the corresponding MCM connector pin on the motherboard.
117+139CERN2014-07-07
Hardware:
replaced MCM 4 SerNr 3951 -> 3151
AnCh3 Bad ADC Data width
Update Tests KS
Update Tests KS
118+67CERN2014-07-07
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Hardware (Analogue problem):
Replaced MCM SerNr 2384 (slot# 12) with MCM SerNr 3162 due to bad FADC data.
Va & KS
119+69CERN2014-07-07
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Hardware (Analogue problem):
Replaced MCM SerNr 2306 (slot# 11) with MCM SerNr 3146 due to bad FADC data on digChan# 1.
VA & KS
120+15CERN2014-07-04
Firmware: DAC offsets for signals going to MCMs 13 & 14 (AnIn 4) set only after several tries. F/w used: Kambiz' latest version.
Victor Andrei
Hardware:
Replaced the following MCMs: * MCM SerNr 1599 (slot# 2) with MCM SerNr 3156 due to bad FADC data on AnChan# 3;
* MCM SerNr 1600 (slot# 3) with MCM SerNr 3157 due to bad FADC data on AnChan# 3;
* MCM SerNr 1601 (slot# 4) with MCM SerNr 3158 due to PHOS4 init errors;
* MCM SerNr 1613 (slot# 4) with MCM SerNr 3159 due to PHOS4 init errors;
VA & KS
121+20CERN2014-07-04
Firmware: DAC offsets for signals going to MCMs 13 & 14 (AnIn 4) set only after several tries. F/w used: Kambiz' latest version.
Victor Andrei
LVDS Tests (full-crate): The debug file is not (yet) uploaded. The module was tested over night, and the size of the produced debug file is larger than the maximum currently admitted by database.
Victor Andrei.
Flash-loader problem:
Problems downloading the firmware from Flash Memory. Problems were seen at CERN and the module was brought back to Heidelberg for more investigations.
Victor Andrei
Loading f/w from the flash memory:
The errors observed at CERN could not be reproduced in HD ATLAS Lab (full-crate set-up, stadalone tools). The loading will also be tested with the online software.
Victor & Klaus
Hardware:
Four SRAM pins not correctly soldered. Problem fixed by KS.
Victor Andrei,
Verification
Retested the module before to send it back to CERN. No error observed
Victor Andrei.
122+47CERN2014-07-04
123+50CERN2014-07-04
124+57CERN2014-07-04
Update Tests KS
Update Tests KS
125+58CERN2014-07-04
Update Tests KS
126+59CERN2014-07-04
Update Tests KS
127+65CERN2014-07-04
Update Tests KS
128+62CERN2014-07-04
Update Tests KS
129+66CERN2014-07-04
Update Tests KS
130+75CERN2014-07-04
Update Tests KS
Update Tests KS
131+126CERN2014-07-04
Firmware
SPI-DAC problems with the old f/w. The module is currently used as test board for the new f/w.
KS & VA
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
MCM Replacement:
All MCMs previously mounted on PPM 126 were removed and brought to CERN to serve as 'MCM spares'. They were replaced on the board with the following MCMs (only SerNr given):
MCM_SlotNr Prev_MCM Current_MCM
# 1 3060 4707
# 2 3061 4708
# 3 3063 4709
# 4 3065 4710
# 5 3066 4711
# 6 3067 4712
# 7 3068 4713
# 8 3069 4714
# 9 3070 4715
# 10 3071 4716
# 11 3072 4717
# 12 3073 4718
# 13 3074 4719
# 14 3075 4720
# 15 3076 4721
# 16 3077 4722
The module will be completely retested with the new MCMs.
Victor Andrei.
MCM changed KS #2 4708 1225 #11 4717 3112
132+160CERN2014-07-04
jkgfkjg
133+28CERN2014-07-03
2 MCMs exchanges: MCM01 #1797 --> #2478 MCM14 #1810 --> #2683
134+48CERN2014-07-03
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
135+61CERN2014-07-03
MCM02 exchanged
136+96CERN2014-07-03
JEP LVDS output errors:
Errors observed at CERN, module brought back to Heidelberg for more investigations.
Victor & Klaus
LVDS Tests:
Bits missing in the LVDS-JEP output of the MCM#1 (bitNr 6/10) and MCM#2 (bitNr 7/10). Replaced MCM#1 (previously serNr 4449, currently serNr 3084) and MCM#2 (previously 4450, currently 3085) and redid the analogue and the digtal tests with the new MCMs.
Victor & Klaus.
Hardware:
Replaced MCM# 6 (SerNr 4458), MCM# 14 (SerNr 4469) and MCM# 16 (SerNr 4472) with the MCMs SerNr 3099, 3109 and 3110 due to bad FADC data.
Victor Andrei
Test Results:
The module was completly retested with the new MCMs. No error was observed.
Victor Andrei
Hardware:
Replaced MCM SerNr 4467 (slot#12) with MCM SerNr 3181 due to bad JEP-LVDS data (bit#5 missing). Also, replaced MCM SerNr 4468 (slot#13) with MCM SerNr 3180 due to bad ASIC readout data.
Victor Andrei
Hardware:
CAN R4k7 implemented.
Update Tests KS
Replaced nMCM #10313 in Slot 10
137+127CERN2014-07-03
138+101CERN2014-07-03
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
139+118CERN2014-07-03
140+119CERN2014-07-03
141+120CERN2014-07-03
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
142+104CERN2014-07-03
143+148CERN2014-07-03
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
144+156CERN2014-07-03
test
Changed MCM after 6Weeks burnin MCM 04 4179->3233 ADC-Bit Err MCM 09 4185->3194 ADC-Bit Err MCM 10 4186->3241 ADC-Bit width
Changed MCM 4178->4750 Bad LVDS Data JP
145+159CERN2014-07-03
Changed MCM after 6Weeks burnin\br MCM 06 4254->3385 Temp. Diode \br MCM 10 4260->3203 Dynamic P4err\br MCM 01 4247->3242 Adc3 BitErr \br
Changed MCM after 6Weeks burnin
MCM 06 4254->3385 Temp. Diode
MCM 10 4260->3203 Dynamic P4err
MCM 01 4247->3242 Adc3 BitErr
146+70CERN2014-05-09
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
147+71CERN2014-05-09
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
148+72CERN2014-05-09
149+73CERN2014-05-09
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
150+74CERN2014-05-09
Update Tests ks
151+147CERN2014-05-09
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Hardware:
Found possible asymmetric LVDS output for MCM# 9, ch# 1. Replaced the MCM (SerNr 4027) with another MCM (SerNr 3100) and redid all tests with the new MCM.
Victor Andrei
The MCM 3061 added to the database according to the MCM list from Taylor
152+5CERN2014-05-08
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
MCM 1462 in MCM13 replaced
1462<->3069
elog link
Pavel Weber
153+6CERN2014-05-08
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
154+8CERN2014-05-08
Firmware: DAC offsets for signals going to MCMs 13 & 14 (AnIn 4) set only after several tries. F/w used: Kambiz' latest version.
Victor Andrei
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
LVDS Tests (Full Crate):
The MCMs in slot#7 (previously serNr 1488, now serNr 2313) and slot#14 (previously serNr 1495, now serNr 2312) were replaced due to bad LVDS data (bad LUT/BCID values, correct parity bit, error probably originating in ASIC).
Victor Andrei
LVDS Tests (Full Crate):
Both analogue and digital tests were redone with the new MCMs.
Victor Andrei
155+27CERN2014-05-08
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
Replaced MCM in slot 6 (previously serNr 1818, currently 2314) due to bad LVDS output (bad data, correct parity bit, error probably generated in ASIC). Both analogue and digital tests were re-done with the new MCM.
Victor Andrei
156+30CERN2014-05-08
Electrical Test: PPM power controller shuts down with additional modules in the crate (i.e. TCM).
Victor Andrei
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
157+42CERN2014-05-08
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
158+93CERN2014-05-08
Hardware
The following MCMs were replaced due to bad ADC data:
* MCM SerNr 4379 (slot# 1) with MCM SerNr 3175;
* MCM SerNr 4380 (slot# 2) with MCM SerNr 3176;
* MCM SerNr 4384 (slot# 5) with MCM SerNr 3177;
* MCM SerNr 4389 (slot# 8) with MCM SerNr 3178.
Victor Andrei
Hardware:
Replaced MCM 2800 (slot# 13) with MCM SerNr 3173 due to a relatively high error rate of PHOS4 initialization.
Victor Andrei
Hardware:
CAN R4k7 implemented. KS
Problem: Do not know MCM Nr. 3 Update Tests KS
159+68CERN2014-05-08
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
160+146CERN2014-05-08
LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei
161-63KS Lab2014-01-31
PHOS4: Cannot initialise PHOS4 ('variable' MCM number), unless powering off several times the module.
Victor Andrei
16280KS-LAB2014-01-31
MCM replacement:
MCMs 2676, 2678 and 2680 (positions 11, 12 and 14) were replaced with MCMs 2782, 2783 and 2784 due to incomplete DB entries for the former MCMs. The PPM was retested (single board tests).
Victor Andrei
back from CERN to repair KS
163+36CERN2010-11-26
MCM replacement
MCM10: 1785<->3063
elog link
Pavel Weber
16483KS-LAB2010-11-23
MCM replacement:
Replaced MCM 2771 with MCM 2781 due to incomplete DB entries for the former MCM. The PPM was retested.
Victor Andrei
Retested in HD OK.
back from CERN to repair KS
165237KS-LAB2010-11-22
166+238ZDC - CERN2010-11-19
167+252ZDC - CERN2010-11-19
168254KIP ATLAS Lab2010-11-19
169-244KS Lab2010-11-18
changed MCM serNr 4745 in slot 9 with MCM serNr 1286. Proble: missing extBCID in readout for analogue channels 1 and 2
changed MCM serNr 4747 in slot 11 with MCM serNr 1287. Problem: failed to configure second bit of the playback memory in the first digital channel.
VA & KS
The power manager switches off the board when the PPM is mounted in a standard ATLAS crate (in the KIP-ATLAS Lab). VA & KS
170129KS-Lab2010-10-19
Hardware:
replaced MCM 3 SerNr 3851 -> 3148 phos4 init error replaced MCM 6 SerNr 3855 -> 3147 Analog Ch1 Bad ADC values replaced MCM 10 SerNr 3863 -> 3149 Serial Interface Problems replaced MCM 12 SerNr 3866 -> 3244 ASIC no Readout Data CAN R4k7 implemented
PPM is in KIP for Repair. MCM01-MCM11 exchanged. CAN-Brd changed to #168. Population as of April 30th 2010
Update Tests KS
171+134CERN2010-10-19
Hardware:
replaced MCM 2 SerNr 3894 -> 3187 JEP LVDS Errors replaced MCM 4 SerNr 3897 -> 3182 phos4 init error CAN R4k7 implemented.
Update Tests KS
17260KS LAB2009-09-18
Canged all good MCMs for repair. Powerup and then shutdown in KSLAB Crate. (5V to low)?
173+91CERN2009-09-18
Hardware:
Replaced the following MCMs:
* MCM SerNr 4339 (slot# 3) with MCM SerNr 3135 due to LVDS clock problems;
* MCM SerNr 4342 (slot# 5) with MCM SerNr 3129 due to ASIC playback errors;
* MCM SerNr 4347 (slot# 9) with MCM SerNr 3130 due to bad JEP-LVDS data;
* MCM SerNr 4348 with MCM SerNr 3132 (bit# 7 permanently missing in the JEP-LVDS output).
VA & KS
Hardware (Ananlogue problems):
Replaced the following MCMs due to bad FADC output:
* MCM SerNr 4338 (slot# 2) with MCM SerNr 3133 --> errors observed on digChan# 2;
* MCM SerNr 4341 (slot# 4) with MCM SerNr 3131 --> errors observed on digChan# 4;
* MCM SerNr 4351 (slot# 12) with MCM SerNr 3136 --> errors observed on digChan# 2;
* MCM SerNr 4353 (slot# 14) with MCM SerNr 3138 --> errors observed on digChan# 4;
VA & KS
LVDS Tests (Full Crate):
Could not upload the latest debug file, because the file is too big. Therefore, the current debug file available in the database describes previous tests. The new file must be uploaded by hand.
Victor Andrei
MCM0 set to Zero must by checked KS
174-24KS Lab2009-07-20
Firmware: DAC offsets for signals going to MCMs 13 & 14 (AnIn 4) set only after several tries. F/w used: Kambiz' latest version.
Electrical Test: (Light) crate's under- or overvoltage protection shuts down the whole crate when powering down the PPM. Not yet understood why.
PHOS4: problems to initialise the PHOS4 of MCM #7. To be investigated, but most probably it's a f/w related issue.
Victor Andrei
removed TTC-Decodercard KS
175-21KS Lab2008-04-29
Firmware: could not load f/w on LCD. Problem not yet understood.
Victor Andrei
176-113KS Lab2008-04-29
Hardware
Power-up controller does not start. Also, problems with the front panel status LED (S1, TTCDec).
KS & VA
177-116KS Lab2008-04-29
Hardware
No VME access.
KS & VA
178-133KS Lab2008-04-29
Hardware
Several AnIn & LCD connectors wrongly soldered. KS & VA
179-143KS Lab2008-04-29